# This is a Revit shared parameter file. # Do not edit manually. # This file has been published by the Revit Standards Foundation, as part of the NLRS (a.k.a Dutch Revit Standards) # As such, this file and it's contest are subject to the same Creative Commons license as the NLRSv2.5.1 # The Revit Standards Foundation, including any of the people contributing to and helping with creating the NLRSv2.5.1, is not liable for any damage to your computer, both hard- and software, caused directly of indirectly by using the NLRSv2.5.1 or any of the files, including the Shared Parameter file. # Even though we ignored Autodesks warning to not edit this file manually… ;-) # So keep calm, while we take over the world # Greetings, Pinky & The Brain *META VERSION MINVERSION META 2 1 *GROUP ID NAME GROUP 1 Common_Angle GROUP 2 Common_Area GROUP 3 Common_Currency GROUP 4 Common_Family Type GROUP 5 Common_Integer GROUP 6 Common_Length GROUP 7 Common_Material GROUP 8 Common_Number GROUP 9 Common_Slope GROUP 10 Common_Text GROUP 11 Common_URL GROUP 12 Common_Volume GROUP 13 Common_Yes/No GROUP 14 Electrical_Apparent Power GROUP 15 Electrical_Current GROUP 16 Electrical_Demand Factor GROUP 17 Electrical_Electrical Potential GROUP 18 Electrical_Load Classification GROUP 19 Electrical_Number of poles GROUP 20 Electrical_Wattage GROUP 21 Energy_Coefficient of Heat Transfer GROUP 22 HVAC_Air Flow GROUP 23 HVAC_Cooling Load GROUP 24 HVAC_Duct Size GROUP 25 HVAC_Heating Load GROUP 26 HVAC_Heating Load divided by Area GROUP 27 HVAC_Temperature GROUP 28 Piping_Fixture Units GROUP 29 Piping_Flow GROUP 30 Piping_Pipe Size GROUP 31 Piping_Pressure GROUP 32 Piping_Temperature GROUP 33 HVAC_Heat Gain GROUP 34 Common_Mass Density GROUP 35 Structural_Mass GROUP 36 Electrical_Power GROUP 37 HVAC_Pressure GROUP 38 HVAC_Power GROUP 39 Electrical_Illuminance GROUP 40 Electrical_Frequency GROUP 41 Structural_Force GROUP 42 Structural_Lineair Force GROUP 43 Energy_Specific Heat GROUP 44 Structural_Area Force GROUP 45 Thermal Resistance *PARAM GUID NAME DATATYPE DATACATEGORY GROUP VISIBLE DESCRIPTION USERMODIFIABLE PARAM 00394d88-9527-4608-81ff-e59dd7ce222b NLRS_P_c09_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 00463da5-51c8-473e-84f8-d316d2073cca NLRS_P_c07_radius LENGTH 6 1 Radius connector 1 PARAM 018aa791-8229-4dde-974d-b1a435ae2c46 NLRS_P_c12_diameter LENGTH 6 1 Diameter connector 1 PARAM 02eea436-c45d-421a-9200-cfe178da28f1 NLRS_E_c01_belastingsklasse LOADCLASSIFICATION 18 1 Belastingsklasse. Bestemd voor connector parameter 'Load Classification' 1 PARAM 031c352e-734d-4049-9ab7-d991902abbd1 NLRS_P_c09_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 03491295-8935-413f-9efc-5fc93c17c787 NLRS_P_c17_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 03b561e9-9422-4d0c-8e6f-9f74d82c14c3 NLRS_E_c01_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 042355d7-65f3-4ff4-842f-8d69a88f7a5d NLRS_P_c05_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 04d3b8d9-e791-49de-a6c0-4cb6861fdf21 NLRS_E_c03_schijnbaar_vermogen_fase_1 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - Unbalanced) 1 PARAM 05073c28-2c68-4282-9993-ff21030aa3f5 NLRS_P_c07_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 05f48ef2-d9e1-4f54-aa1b-9bafd25fadab NLRS_E_c01_actief_vermogen ELECTRICAL_POWER 36 1 Actief vermogen 1 PARAM 061d2730-d85f-462a-847a-27404bbc525e NLRS_E_c02_actief_vermogen ELECTRICAL_POWER 36 1 Actief vermogen 1 PARAM 068b7167-6d2a-4605-a2a7-978bde04eae0 NLRS_P_c16_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 06cd05fd-e187-4346-a95e-eee9e84b739f NLRS_P_c17_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 07203f75-a7f8-493c-88d4-a42135d99008 NLRS_P_c01_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 076f2560-ab6f-41b6-a616-a7d084f35cad NLRS_P_c01_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 07a59bfd-5f64-4d37-b7d4-464057cdae77 NLRS_P_c16_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 09f58cb2-e50d-4e42-b32c-66bb6835d2f9 NLRS_M_c01_radius LENGTH 6 1 Radius connector 1 PARAM 0a1222d3-46a9-4ae1-a2a3-5d29e91df6a8 NLRS_P_c04_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 0ad57474-74e2-4e7d-bfaa-4e8279c61c6a NLRS_P_c03_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 0b52777a-ef6a-4aa5-9575-4c78d2bbbea2 NLRS_E_c02_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 0b809693-d133-406d-9cd8-fb8c41e52952 NLRS_M_c05_diameter LENGTH 6 1 Diameter connector 1 PARAM 0e0f75eb-a640-4a81-ba31-eb69de3cdd35 NLRS_P_c04_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 107a0f01-d6f4-4bce-b527-c816e0c8ed5b NLRS_P_c02_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 1159d621-ddf2-4a1a-96de-907de2a07560 NLRS_P_c08_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 11a5f68f-f68a-4986-a10b-4e27d0d947af NLRS_E_c02_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter. 'Angle' bij Conduit- en Cable Tray connectoren) 1 PARAM 120035ec-a764-4517-918e-036ea7129c4e NLRS_E_c05_schijnbaar_vermogen ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - balanced) 1 PARAM 12b21117-a8a1-4c66-b492-77e293b4a62f NLRS_P_c09_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 1343d3cf-13db-415f-b6c7-10c8c4fa6ddc NLRS_P_c02_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 138a436e-e960-48a0-9659-e197879057a7 NLRS_E_c05_DC YESNO 13 1 Spanningstype (gelijkstroom) 1 PARAM 13c08d8a-2674-454a-ab43-c98d25cd358b NLRS_E_c03_diameter LENGTH 6 1 Diameter connector (veelal bij Conduit Fittings) 1 PARAM 141be6f1-76bf-4beb-a467-04ed9ce913f4 NLRS_P_c09_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 16031e54-24e2-4dc1-ae64-98782fd29fe5 NLRS_E_c05_subklasse_motor YESNO 13 1 Wanneer de electrical connector de connector is van een motor dan moet dit aangevinkt staan. Ongetwijfeld wordt hier gebruik van gemaakt bij load classification. 1 PARAM 160643bd-014a-4fec-b750-c4186a3a65d9 NLRS_P_c04_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 16452187-2e40-48f9-b767-bedf08394a88 NLRS_E_c04_spanning ELECTRICAL_POTENTIAL 17 1 Spanning van de connector. (is een te koppelen parameter. 'Voltage' bij Electrical connectoren) 1 PARAM 1804f55e-6164-4e67-9aed-eb0199e461c5 NLRS_P_c01_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 185d5283-6965-4f0c-98e6-f7aea22fa013 NLRS_P_c01_belastingswaarde_eenheid INTEGER 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 187ec56d-f43a-4d7a-8477-47c795e45213 NLRS_E_c02_spanning ELECTRICAL_POTENTIAL 17 1 Spanning van de connector. (is een te koppelen parameter. 'Voltage' bij Electrical connectoren) 1 PARAM 18cd09ea-1bbb-40cf-97f7-734fdcc77032 NLRS_P_c11_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 190c5a21-62c8-4e86-98e4-f7f2933a5f0f NLRS_P_c15_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 195805c2-ece2-4d9f-acd3-bad7f02b7421 NLRS_E_c04_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 1a23be9a-d365-4062-a7b7-41faaf940e69 NLRS_P_c10_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 1b216d3b-4dbe-44f3-8e87-189a5f7191bc NLRS_P_c06_diameter LENGTH 6 1 Diameter connector 1 PARAM 1b3f157e-3ec3-494e-9292-dd319ecb711c NLRS_P_c14_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 1b7bed05-7f4d-46e9-a459-e779c867366c NLRS_P_c12_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 1c30cb24-145b-43a4-a6fb-1018b938b9a7 NLRS_P_c10_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 1c712c6b-2a7f-48e0-9a3f-e12ded70db89 NLRS_M_c04_drukverlies_statisch HVAC_PRESSURE 37 1 Statisch drukverlies connector 1 PARAM 1df64691-9069-4179-90de-c28580ce137f NLRS_P_c13_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 1dfc0b1c-56cf-4177-b7c3-a72c8cb1c429 NLRS_P_c18_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 1e1eb95f-8893-4cbe-a899-ca5019fee915 NLRS_P_c10_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 1e79311b-850a-4ad7-a68b-6a7384912417 NLRS_P_c07_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 1e94f534-f4b9-444d-9678-b66dcfeda725 NLRS_P_c17_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 1ea3c4f1-908b-4409-8be4-f1c0954b8c3f NLRS_P_c09_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 1f53d955-f4f0-478b-9010-4df1aacd7b53 NLRS_P_c02_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 1f7942ab-563f-4b3b-bfc1-f758a7142ec7 NLRS_E_c03_schijnbaar_vermogen_fase_3 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_3 op connector (Power - Unbalanced) 1 PARAM 1fba5547-4df8-4e60-b544-a7968bb263e2 NLRS_P_c18_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 2012df7d-1a79-48bf-a8fe-54e150262730 NLRS_P_c15_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 21487444-78fc-4836-8a0b-d932d04a51cd NLRS_P_c09_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 21ea6aa9-3a8b-43f5-9d3b-c30eb6d46995 NLRS_M_c01_drukverlies_statisch HVAC_PRESSURE 37 1 Statisch drukverlies connector 1 PARAM 224e68b8-a1c9-464d-99bd-f5be6e0082f5 NLRS_P_c03_diameter LENGTH 6 1 Diameter connector 1 PARAM 22725af2-3894-4f8b-b989-e3964a1d8821 NLRS_P_c06_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 22a8b761-9a12-4f6a-9e12-20c7564481e0 NLRS_P_c05_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 23b7aca8-b987-44b9-b121-cba13aad5ea5 NLRS_P_c13_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 24530354-056e-4708-a41f-5e00d13911dc NLRS_E_c03_AC YESNO 13 1 Spanningstype (wisselstroom) 1 PARAM 24866206-73be-4d45-b1d8-37569aece2a7 NLRS_P_c17_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 24d50fb3-f1f8-4728-810b-d3e50bcecb73 NLRS_P_c05_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 25e57b0d-b5b7-4653-b826-a3a969e107e3 NLRS_P_c11_diameter LENGTH 6 1 Diameter connector 1 PARAM 2613a164-5b21-420e-b904-64ac2f4f08ef NLRS_E_c04_belastingsklasse LOADCLASSIFICATION 18 1 Belastingsklasse. Bestemd voor connector parameter 'Load Classification' 1 PARAM 263aff91-e9e2-43b3-8d46-6271d3937369 NLRS_E_c03_schijnbaar_vermogen_fase_2 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_2 op connector (Power - Unbalanced) 1 PARAM 265e820b-cb86-4c62-b2a8-43efb06bedf7 NLRS_P_c14_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 26d86fcd-9a15-49af-bbb2-8c6c9b52cda2 NLRS_P_c09_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 2714eecf-351d-4e9f-8c4f-348a707e707e NLRS_P_c05_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 2769e4f7-cfbd-4256-ac50-d4eda29bc2ab NLRS_M_c01_temperatuur HVAC_TEMPERATURE 27 1 Temperatuur medium dat door connector stroomt 1 PARAM 277e2750-cd7a-485c-8107-530a000b7d99 NLRS_P_c15_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 287410f7-65ac-4ce9-b15a-aa337e9569ee NLRS_E_c05_diameter LENGTH 6 1 Diameter connector (veelal bij Conduit Fittings) 1 PARAM 28b50a92-1d84-48ea-8f55-81b0dc95a795 NLRS_E_c01_hoogte LENGTH 6 1 Hoogte connector (veelal bij Cable Tray Fittings) 1 PARAM 28b59108-9310-4415-9132-c9d44e58f140 NLRS_P_c15_radius LENGTH 6 1 Radius connector 1 PARAM 290faf37-5d3b-4fa2-b7c3-c7b4294ef4a4 NLRS_P_c10_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 29c93c37-06e6-481f-89f4-20b6931ae2da NLRS_M_c03_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 2a9346f3-f3a8-4d4c-ae6b-fbe56e3a30dd NLRS_P_c11_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 2af0ed8e-62e3-4145-95d6-bb8128184c20 NLRS_E_c01_spanning ELECTRICAL_POTENTIAL 17 1 Spanning van de connector. (is een te koppelen parameter. 'Voltage' bij Electrical connectoren) 1 PARAM 2b81d626-772e-4c23-b04d-b2fb77cbc6dc NLRS_P_c16_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 2bcd1295-2f5c-45d5-b484-ace7342bd826 NLRS_E_c03_subklasse_motor YESNO 13 1 Wanneer de electrical connector de connector is van een motor dan moet dit aangevinkt staan. Ongetwijfeld wordt hier gebruik van gemaakt bij load classification. 1 PARAM 2be1082c-5657-4f63-a111-2b831a348e83 NLRS_E_c02_belastingsklasse LOADCLASSIFICATION 18 1 Belastingsklasse. Bestemd voor connector parameter 'Load Classification' 1 PARAM 2c58e58b-bc8b-486a-b438-0727d0fcb5cd NLRS_E_c03_belastingsklasse LOADCLASSIFICATION 18 1 Belastingsklasse. Bestemd voor connector parameter 'Load Classification' 1 PARAM 2c6e5b8c-ca87-46f8-8b52-1064a41453b9 NLRS_E_c01_subklasse_motor YESNO 13 1 Wanneer de electrical connector de connector is van een motor dan moet dit aangevinkt staan. Ongetwijfeld wordt hier gebruik van gemaakt bij load classification. 1 PARAM 2cb93cae-d707-433c-bd7d-e5d443561813 NLRS_P_c11_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 2d146de0-1a6b-4c1e-a53f-6f24bd7b80d8 NLRS_P_c04_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 2d558494-c2d1-4ce7-8f1d-d683f901f921 NLRS_M_c05_geluidsvermogenniveau INTEGER 5 1 Het geluidsvermogenniveau uitgedrukt in dB dat via deze connector de component verlaat (connector out) of op de component binnenkomt via deze connector (connector in) 1 PARAM 2d84533c-3da4-4733-b966-76e85d5bad44 NLRS_P_c05_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 2e1db7fc-f9c3-44c3-9d07-d35d8a316772 NLRS_E_c01_diameter LENGTH 6 1 Diameter connector (veelal bij Conduit Fittings) 1 PARAM 2e1f5626-a625-43f0-823d-7ec78d04d7ec NLRS_P_c15_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 2eca48a1-8623-44af-8720-41688f307924 NLRS_E_c02_hoogte LENGTH 6 1 Hoogte connector (veelal bij Cable Tray Fittings) 1 PARAM 2f18c417-b19b-4c39-aa1a-5aea626db704 NLRS_P_c07_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 2f1c4fcb-80ae-48af-8996-407711827f5f NLRS_M_c04_vrije_doorlaat NUMBER 8 1 Uitgedruk in %. Hoeveel % van de oppervlakte van een luchtrooster biedt geen obstakel voor de luchtstroom 1 PARAM 3056f80a-e91d-4712-898e-b158fbbb80f7 NLRS_P_c10_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 30769d59-6e2f-4297-b462-111867f66869 NLRS_P_c15_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 30a4be06-0494-472e-984f-1d0a4da20ef6 NLRS_P_c18_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 30b6a103-02a4-4fbc-b097-6fc73295915d NLRS_M_c01_vrije_doorlaat NUMBER 8 1 Uitgedruk in %. Hoeveel % van de oppervlakte van een luchtrooster biedt geen obstakel voor de luchtstroom 1 PARAM 30fed3ac-f87e-4f10-ad88-1992f066ba4d NLRS_P_c10_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 3130b769-a66f-4ac3-a23d-f49d67faad00 NLRS_P_c04_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 31ef848e-2913-4a6b-a45b-b50988cbdd7f NLRS_E_c01_DC YESNO 13 1 Spanningstype (gelijkstroom) 1 PARAM 3243bbb9-2670-426b-b60d-efe12ae7375d NLRS_P_c17_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 3252d4dd-cfe9-44b8-b9a5-abfb8d2b9f81 NLRS_P_c03_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 327b5aec-2cc3-4aec-a12c-8414b274db59 NLRS_P_c16_diameter LENGTH 6 1 Diameter connector 1 PARAM 32ca9311-e991-4230-9d8f-337907b6bd3b NLRS_E_c05_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter. 'Angle' bij Conduit- en Cable Tray connectoren) 1 PARAM 33871af1-2691-427b-a2d9-5f256f9622cc NLRS_P_c14_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 35f3ee8d-a6d0-48cf-8d56-850340288984 NLRS_P_c03_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 36056ab8-acbd-4c3a-9075-6bb94ac25f51 NLRS_E_c01_radius LENGTH 6 1 Radius connector (veelal bij Conduit Fittings) 1 PARAM 363755dc-00e4-432e-9cd7-61f02c649f32 NLRS_P_c13_radius LENGTH 6 1 Radius connector 1 PARAM 36b42947-de3c-438d-9584-6f6fb2d925d9 NLRS_P_c11_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 36cb659b-9be5-4508-8065-6a58498712bf NLRS_E_c05_breedte LENGTH 6 1 Breedte connector (veelal bij Cable Tray Fittings) 1 PARAM 3748ce11-3e53-436d-9a74-4165af597298 NLRS_P_c14_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 37ab9e02-e925-42df-a6bf-2ab0b7908918 NLRS_M_c03_hoogte LENGTH 6 1 Hoogte connector 1 PARAM 380016e3-4b24-4314-bb3c-1bd072327a75 NLRS_E_c04_schijnbaar_vermogen_fase_1 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - Unbalanced) 1 PARAM 38c7ee91-33e0-4d34-a00d-dae4aaec64ca NLRS_P_c15_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 3927daf7-6b22-4b1d-b7b1-a764bc3bcc91 NLRS_M_c02_radius LENGTH 6 1 Radius connector 1 PARAM 3b5e24eb-2787-4857-b761-a99b32c9377e NLRS_P_c07_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 3c749bc5-e71a-406a-9a37-4a8249c357fc NLRS_P_c18_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 3cc7adeb-5be6-4196-b429-45e1ee12fbc7 NLRS_E_c02_subklasse_motor YESNO 13 1 Wanneer de electrical connector de connector is van een motor dan moet dit aangevinkt staan. Ongetwijfeld wordt hier gebruik van gemaakt bij load classification. 1 PARAM 3d42557e-00b0-4c65-b5d5-e98c8d7ed486 NLRS_P_c18_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 3d7cd4db-346c-4306-b41c-441de0bf8397 NLRS_P_c11_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 3dc46dbd-dbcb-4098-8df5-73f8c6f25d0c NLRS_E_c05_hoogte LENGTH 6 1 Hoogte connector (veelal bij Cable Tray Fittings) 1 PARAM 3e584978-1200-4050-b192-9239db9021f9 NLRS_P_c18_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 3f6d0dbf-34a1-45f5-9f83-93f03640e08c NLRS_P_c06_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 40543dd0-a797-4766-90aa-a7ad50326fd7 NLRS_E_c01_aantal_fasegeleiders INTEGER 19 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM 40bf4da4-628a-42a9-8408-f44a11acf420 NLRS_E_c05_schijnbaar_vermogen_fase_1 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - Unbalanced) 1 PARAM 40f69abf-1ad6-41d9-bb0e-efba48e81fb8 NLRS_E_c05_verbruiker_driehoek_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 41e9b122-f859-4a9e-92c2-cfafe61827af NLRS_P_c01_diameter LENGTH 6 1 Diameter connector 1 PARAM 41fc1e40-574e-40fb-8c34-18224335132f NLRS_P_c06_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 428ddb9b-f3a6-43b0-9e48-36cd3087fc89 NLRS_P_c14_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 4460da74-3bf4-4dc1-9fb9-615b51ced10f NLRS_P_c09_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 4468c7de-8886-4891-aebd-d0a0e7064039 NLRS_P_c16_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 449766ea-bb09-4300-a7e0-6cf322a21d9a NLRS_P_c18_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 44c41694-f8b8-4def-98ad-22d15262304e NLRS_P_c07_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 453d3f39-0021-43e8-bbe8-b6b2c6c350d6 NLRS_P_c12_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 45716c6f-67c8-4674-8366-578e1bcfcc8c NLRS_P_c09_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 45ff5059-5179-44f9-b5a6-0f09e5fcbc77 NLRS_P_c15_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 461c447a-35ae-4983-8688-6ade64aaa56b NLRS_E_c05_belastingsklasse LOADCLASSIFICATION 18 1 Belastingsklasse. Bestemd voor connector parameter 'Load Classification' 1 PARAM 464c6977-6eb0-43f3-9784-caf90b62dbae NLRS_P_c06_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 474d0584-2393-4f1c-a02c-2c2c6a72efb7 NLRS_P_c04_radius LENGTH 6 1 Radius connector 1 PARAM 47f4d47b-b538-4ef5-b922-5defbe3570d3 NLRS_P_c08_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 4c87e608-7216-45a3-b494-0dd0270d195f NLRS_P_c04_diameter LENGTH 6 1 Diameter connector 1 PARAM 4def3488-159b-4ac9-ba61-9c0b90a91b4d NLRS_E_c05_AC YESNO 13 1 Spanningstype (wisselstroom) 1 PARAM 4e806468-3b59-42e4-a47f-1205af3f88be NLRS_P_c05_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 503946e3-9cf1-4aa7-89b8-393e7c7c3d21 NLRS_E_c05_radius LENGTH 6 1 Radius connector (veelal bij Conduit Fittings) 1 PARAM 505a6b40-928c-4086-b7da-55bd3177057e NLRS_P_c03_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 50e2fd9c-5692-48e6-be5e-26def1c6ddfd NLRS_M_c04_hoogte LENGTH 6 1 Hoogte connector 1 PARAM 51002987-abf2-4a9e-a965-a3f595c18fc1 NLRS_P_c08_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 5125e88e-f243-4ac0-8f4d-5e00c0ba988c NLRS_M_c04_geluidsvermogenniveau INTEGER 5 1 Het geluidsvermogenniveau uitgedrukt in dB dat via deze connector de component verlaat (connector out) of op de component binnenkomt via deze connector (connector in) 1 PARAM 513e0ebe-019e-4a9f-b67b-a326862a6923 NLRS_P_c04_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 5183dc19-4900-476f-bfd5-6bd16264301d NLRS_P_c12_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 518ae6e9-0a9a-4adf-b090-32953f80d659 NLRS_P_c03_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 520534d6-5c8b-487e-812f-776227c7751b NLRS_P_c13_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 522a82b5-33df-4454-b760-0ec3e1a1f7ab NLRS_E_c02_schijnbaar_vermogen_fase_1 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - Unbalanced) 1 PARAM 526c0c69-1e70-448d-8fbf-0720940bd614 NLRS_P_c14_diameter LENGTH 6 1 Diameter connector 1 PARAM 533c61b8-09de-4e17-b100-a5d89b795bab NLRS_M_c03_drukverlies_statisch HVAC_PRESSURE 37 1 Statisch drukverlies connector 1 PARAM 53970e47-9bf3-4315-8c17-fff339d1444a NLRS_M_c05_hoogte LENGTH 6 1 Hoogte connector 1 PARAM 53e6a8d6-d265-4b75-a8df-c896bd47495f NLRS_P_c02_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 547a3fa2-72e4-429e-ae83-efdb6c1eda53 NLRS_E_c04_stroom ELECTRICAL_CURRENT 15 1 Nominale stroom van connector 1 PARAM 555d291f-d167-4fab-b16f-3e523ec0df64 NLRS_P_c02_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 55aa56a1-dedb-4efb-a727-994cabeed3f1 NLRS_P_c02_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 5638ff10-b95f-49e8-aa94-f20c9f5be683 NLRS_M_c03_breedte LENGTH 6 1 Breedte connector 1 PARAM 56a5b74e-7760-4304-8f1c-634a1dae9a9d NLRS_M_c05_straal LENGTH 6 1 Radius connector 1 PARAM 571d2f18-dfcf-4f40-933d-5072616cbd16 NLRS_P_c05_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 57a8240a-6ce3-4552-99af-c3b54d31ad09 NLRS_E_c02_aantal_fasegeleiders INTEGER 19 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM 59f0ab22-5e7e-4252-a296-f5cf244cfc79 NLRS_M_c02_diameter LENGTH 6 1 Diameter connector 1 PARAM 5b3367f4-a1ee-45c0-b778-ef13c32d946f NLRS_M_c01_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 5b4f8ea3-35c6-4713-8e46-851effe1c239 NLRS_P_c01_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 5b8d6ac4-0bdb-4a1c-bfb5-c089d6b56688 NLRS_P_c10_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 5c613e82-fddb-4894-aad0-7a8adc2c8e06 NLRS_P_c16_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 5ced373e-e07a-47f8-a9a6-88562ba7fb30 NLRS_P_c02_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 5e55c0ae-56c4-4c17-9a4c-a7c3762fac4c NLRS_P_c03_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 5f566677-02f3-47cd-9f08-09f58b3df542 NLRS_P_c18_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 5f962e4a-d3b9-4077-9ded-57568e6362de NLRS_E_c03_radius LENGTH 6 1 Radius connector (veelal bij Conduit Fittings) 1 PARAM 5ffca73b-b0a0-4421-9e33-b37f31cfb18b NLRS_E_c04_verbruiker_ster_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 6181d533-9667-41b8-8ea0-52aea8c590d1 NLRS_E_c02_verbruiker_ster_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 6189f3e8-1f46-42ed-a446-69b1f55973a4 NLRS_P_c16_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 627fba57-92f4-49be-a016-5d008a939806 NLRS_P_c02_diameter LENGTH 6 1 Diameter connector 1 PARAM 62a4ca27-3e2c-4043-b643-b6e53df3375d NLRS_P_c11_radius LENGTH 6 1 Radius connector 1 PARAM 63483135-bfe7-4422-b75e-d79b942aa435 NLRS_M_c05_breedte LENGTH 6 1 Breedte connector 1 PARAM 64315001-9978-4154-8fad-ffc7478cc0b0 NLRS_P_c12_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 65041b5d-c707-4ef9-abd7-1d632fb679f9 NLRS_P_c02_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 658548a9-1e35-401c-ae4f-7ce51eacba0d NLRS_P_c15_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 65c88658-2fc8-49dc-bed0-d9748b74ea45 NLRS_P_c05_diameter LENGTH 6 1 Diameter connector 1 PARAM 66f6d9b0-4036-4da3-b0dd-785795ef578e NLRS_P_c15_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 6737706f-424d-4717-8e57-c7d5aac78498 NLRS_E_c03_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 6779b14b-8c0f-43e4-ae0d-0616253cf097 NLRS_E_c02_verbruiker_driehoek_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 68452c87-d99b-49c3-94c2-d790dc565e7b NLRS_P_c07_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 691b2f88-96d0-4405-9f65-20502c17dffb NLRS_P_c02_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 6923a615-3c29-4ba9-8a9f-d2cfd35204bb NLRS_E_c04_schijnbaar_vermogen_fase_3 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_3 op connector (Power - Unbalanced) 1 PARAM 694bf8b4-8ec7-4607-bf85-5296a4addd5a NLRS_P_c11_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 69d2a663-79f6-410f-af31-84d221c06163 NLRS_E_c04_aantal_fasegeleiders INTEGER 19 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM 6a6dac14-bf97-4106-87f9-7f02507e2438 NLRS_M_c04_temperatuur HVAC_TEMPERATURE 27 1 Temperatuur medium dat door connector stroomt 1 PARAM 6bbc3f5a-3940-4d3a-adee-f0382ace22a9 NLRS_M_c03_vrije_doorlaat NUMBER 8 1 Uitgedruk in %. Hoeveel % van de oppervlakte van een luchtrooster biedt geen obstakel voor de luchtstroom 1 PARAM 6c0fcb89-9983-44f9-b827-8cb61534bdd6 NLRS_M_c03_geluidsvermogenniveau INTEGER 5 1 Het geluidsvermogenniveau uitgedrukt in dB dat via deze connector de component verlaat (connector out) of op de component binnenkomt via deze connector (connector in) 1 PARAM 6c6de55a-9a20-42ff-8bcc-4e967e66a33c NLRS_P_c08_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 6cd737ad-946e-46bf-bfb8-910806d5a9b3 NLRS_P_c14_radius LENGTH 6 1 Radius connector 1 PARAM 6da5df6e-ab24-4202-b09d-414cb0d70828 NLRS_P_c08_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 6da5df6e-ab24-4202-b09d-414cb0d70828 NLRS_P_c09_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 6e89aab4-90b4-45bf-aba6-770d115f3aa6 NLRS_M_c05_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 6ec0020e-d4ba-488b-98e7-7336abb503c9 NLRS_P_c10_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 6ec2e54d-6a3d-487c-88d1-ad4aa4c0f92d NLRS_P_c05_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 6ed05951-cbd8-4d65-9fb2-78b96e0a9add NLRS_P_c03_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 70cf8f18-8c10-4708-ae69-470f0cee74b9 NLRS_P_c10_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 718a87f1-9966-41f2-a62b-f8d664c33239 NLRS_E_c05_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 71a7b447-adb7-4be6-8708-9f73bec0ec7a NLRS_P_c05_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 71f5dcbe-f51f-4ff2-8534-c0b8bd26f7fa NLRS_P_c04_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM 72f91a88-9df4-4ec3-b91e-7b829a4eb691 NLRS_M_c01_breedte LENGTH 6 1 Breedte connector 1 PARAM 73bbac62-8381-43ee-9262-1c36c3e79ac9 NLRS_P_c15_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 73e170df-4fb7-433a-9d5e-36c321889f8f NLRS_E_c01_schijnbaar_vermogen_fase_1 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - Unbalanced) 1 PARAM 73ef1dbb-a8c1-42ac-9356-2d9dc248208b NLRS_P_c05_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 7407d46c-9034-431d-89ce-989d6518df95 NLRS_E_c01_verbruiker_driehoek_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 741ce4f8-9236-4f90-8b92-64c63c964347 NLRS_E_c01_aantal_polen NOOFPOLES 5 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM 74459998-92ed-406e-8d72-1c8e09f3f5d0 NLRS_P_c17_diameter LENGTH 6 1 Diameter connector 1 PARAM 74a19fe4-8ae8-43ea-9069-85e05fd5e07d NLRS_P_c08_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 74c0096b-551c-4add-8bd5-4444f924db5b NLRS_P_c18_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM 77b59d63-dd06-4787-85b3-5d072dc83515 NLRS_P_c07_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 78d6f915-d27a-49f7-89be-517addb61cfb NLRS_P_c09_diameter LENGTH 6 1 Diameter connector 1 PARAM 79578f2f-bbd7-4d2c-b7a9-0d1b75ff1cc4 NLRS_M_c01_geluidsvermogenniveau INTEGER 5 1 Het geluidsvermogenniveau uitgedrukt in dB dat via deze connector de component verlaat (connector out) of op de component binnenkomt via deze connector (connector in) 1 PARAM 797815fa-c2c4-449f-9fe2-a04dd5861893 NLRS_P_c07_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 7b15233f-eaed-4ddf-9431-2cd6262118d5 NLRS_M_c01_hoogte LENGTH 6 1 Hoogte connector 1 PARAM 7b665bec-348c-4d4c-9c00-048b63faaf34 NLRS_E_c01_verbruiker_ster_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 7c3d7fc1-a630-4d9b-8873-225a3c70ea66 NLRS_E_c01_schijnbaar_vermogen ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - balanced) 1 PARAM 7c9c6706-7ab3-4e64-9c5a-24a4a7cdf464 NLRS_P_c18_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM 7cbd49b3-b2e9-4760-9809-09a9642989dc NLRS_P_c16_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 7d58e614-df7f-4081-8e1c-8e3e86e14f1a NLRS_P_c03_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 7d64e9a1-79a5-4935-9862-363794bae02f NLRS_P_c14_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM 7df42a15-78f0-4319-baf9-57cf6a9c8423 NLRS_P_c12_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 7f5eb340-00a0-4701-9ae3-19a48d86df0a NLRS_P_c17_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM 7fbd2c72-749d-4615-940a-97185744648a NLRS_P_c11_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 8078eae0-3067-40ee-9c4c-2db54ef1cfa5 NLRS_M_c03_diameter LENGTH 6 1 Diameter connector 1 PARAM 8084f237-d688-4a2d-b3af-0ff4882cb268 NLRS_P_c14_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 81578e75-d355-47fe-a5e5-8c35ed937cc6 NLRS_P_c08_diameter LENGTH 6 1 Diameter connector 1 PARAM 8232e231-22bf-4f79-b9f6-57ecf2ace805 NLRS_P_c12_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 8239be76-59be-4172-b0ff-bf4ebe8031d4 NLRS_E_c03_schijnbaar_vermogen ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - balanced) 1 PARAM 823d64b3-ac35-472b-a500-dfc98c72e528 NLRS_P_c06_radius LENGTH 6 1 Radius connector 1 PARAM 83a294f9-b51c-4c74-b52b-99eb0b8f829f NLRS_P_c11_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 841bf10e-6dce-47e0-873e-1018944af70f NLRS_E_c03_verbruiker_driehoek_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM 8495a35e-31b6-46f8-8db0-1d4b55facd7c NLRS_E_c02_DC YESNO 13 1 Spanningstype (gelijkstroom) 1 PARAM 8547d7ad-2ca0-4d4c-9cf2-f0aa05085983 NLRS_P_c11_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 85ee129d-e67a-48bf-9178-aa14bc4be0ea NLRS_P_c06_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 87964ebd-4c16-4b29-9873-02414957a455 NLRS_M_c02_hoogte LENGTH 6 1 Hoogte connector 1 PARAM 879d4f17-6453-4a13-9d78-dbd7dbc0ca92 NLRS_E_c03_actief_vermogen ELECTRICAL_POWER 36 1 Actief vermogen 1 PARAM 89203bcb-6116-4eed-bb39-47db85cd097f NLRS_P_c14_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 8991cb2c-4e06-4c9c-8bf9-a4403dd18507 NLRS_P_c10_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 8b9df666-b38e-4352-9135-5b905482db1a NLRS_M_c04_straal LENGTH 6 1 Radius connector 1 PARAM 8be3a912-db6c-47ba-9efd-f86abdf28c83 NLRS_P_c13_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM 8bef0afd-b724-474c-bb69-a99ba11f7dd2 NLRS_P_c12_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM 8c168365-a7e3-4678-9ccf-80a884f93731 NLRS_P_c06_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 8d743064-b760-4230-9c07-7b5078143860 NLRS_P_c17_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 8e881783-b2e4-403c-ab98-554c4e2223ff NLRS_P_c15_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM 8fc6bc89-4dd0-4c5e-a37c-b70430d8d81f NLRS_P_c08_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM 912b9524-554e-4d0e-8fca-b77d099eae43 NLRS_P_c07_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 914d0e42-9c56-4a1a-86c9-67da4e9d7682 NLRS_E_c04_schijnbaar_vermogen_fase_2 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_2 op connector (Power - Unbalanced) 1 PARAM 91aea8f2-7252-44be-8874-ac4188bee3e0 NLRS_P_c12_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM 9272b570-8e60-4418-afc0-ffd0f706db87 NLRS_E_c03_spanning ELECTRICAL_POTENTIAL 17 1 Spanning van de connector. (is een te koppelen parameter. 'Voltage' bij Electrical connectoren) 1 PARAM 93eddee9-dd79-4a20-bfe0-9d5c832fe7a8 NLRS_P_c06_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM 940a7cd1-ccef-4254-80d5-b23882dca766 NLRS_E_c03_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter. 'Angle' bij Conduit- en Cable Tray connectoren) 1 PARAM 940d51e8-e0f0-477b-ae6a-c290029b062f NLRS_P_c11_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 94658006-6341-43f5-a7d6-afd33654b43f NLRS_P_c13_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 94dd35a0-8b34-4844-a6cc-42fc171d7a85 NLRS_P_c10_radius LENGTH 6 1 Radius connector 1 PARAM 9505f381-b264-484e-bc35-423162aaa2b6 NLRS_P_c10_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM 963c5d67-36b3-4c8e-afe0-ec9589edd34b NLRS_P_c16_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM 97583319-947e-4c5b-ac75-a8cb8224e750 NLRS_P_c06_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 97ccfc10-1b89-4033-b7e7-9d3ed505e0f0 NLRS_M_c02_breedte LENGTH 6 1 Breedte connector 1 PARAM 9831d7be-2aab-4536-bdea-850f17faacba NLRS_P_c03_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM 992913c6-111b-4fbb-b77b-4a988c452d1e NLRS_P_c06_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 996c24b7-9222-4825-9187-922bad38ce01 NLRS_P_c08_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM 999ce11c-c68d-4b62-9ae6-05e716f50e52 NLRS_P_c01_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM 9a3dc79b-ae98-49b6-822a-409d04d4509e NLRS_M_c02_drukverlies_statisch HVAC_PRESSURE 37 1 Statisch drukverlies connector 1 PARAM 9a5d1158-a9a1-4942-a650-1c24a032fd99 NLRS_E_c02_AC YESNO 13 1 Spanningstype (wisselstroom) 1 PARAM 9aac1dd2-76f8-4c5e-9660-49968357c602 NLRS_P_c01_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM 9b3762be-4259-4662-b4cc-80a079e06cba NLRS_E_c02_aantal_polen NOOFPOLES 5 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM 9b71631c-7302-406a-811c-7c49c335bfa0 NLRS_P_c06_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM 9dc25da3-0702-4ed7-932c-4350dbbfce25 NLRS_E_c02_stroom ELECTRICAL_CURRENT 15 1 Nominale stroom van connector 1 PARAM a03e5a36-6806-455e-9d13-d53de4a529a5 NLRS_P_c02_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM a3814cf6-7053-4044-bb42-1bf5b8744015 NLRS_P_c01_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM a42048f8-bf86-4949-82cb-34e2ca0dbb69 NLRS_P_c06_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM a5b4930b-1cd4-4b18-9ef3-bb760d2c74d6 NLRS_P_c09_radius LENGTH 6 1 Radius connector 1 PARAM a6237dee-0a58-4e74-84ee-0d4138847aa0 NLRS_P_c05_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM a6473886-e2a6-4e33-9d6b-ff17e54df72a NLRS_M_c02_geluidsvermogenniveau INTEGER 5 1 Het geluidsvermogenniveau uitgedrukt in dB dat via deze connector de component verlaat (connector out) of op de component binnenkomt via deze connector (connector in) 1 PARAM a6556b48-0f10-4e07-b8d7-35d79220fbf2 NLRS_E_c01_breedte LENGTH 6 1 Breedte connector (veelal bij Cable Tray Fittings) 1 PARAM a6650dde-57cb-4913-81c9-fca8debb4148 NLRS_E_c04_radius LENGTH 6 1 Radius connector (veelal bij Conduit Fittings) 1 PARAM a6d45bdb-13dd-4af4-94ab-9dcebe12431a NLRS_P_c12_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM a76c3fd8-7f3c-494c-a3e1-b2d119d4e12f NLRS_P_c08_radius LENGTH 6 1 Radius connector 1 PARAM a78b3ddc-514b-46e0-af6d-1597cb876889 NLRS_P_c09_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM a7bb754d-abae-41c3-a7b3-436725aac2fc NLRS_P_c14_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM a812b624-4a24-44df-9404-7054c86f4b02 NLRS_P_c03_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM a82aacc3-558f-4861-924d-492415e7c3c1 NLRS_P_c07_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM a82b3b67-4063-48b0-9d70-aa257037466f NLRS_P_c02_radius LENGTH 6 1 Radius connector 1 PARAM a852ccf9-4f43-4b91-a734-b056ca5c8763 NLRS_P_c16_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM a88c1891-65e1-4940-a28c-3aced38a1dc5 NLRS_M_c01_diameter LENGTH 6 1 Diameter connector 1 PARAM a8faa4e1-6879-4663-8768-cab16a464f71 NLRS_P_c08_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM aad81075-90b0-4fb1-8e9d-c41a5c22594a NLRS_P_c16_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM ab21f387-baa2-42f3-b51a-501a91163d59 NLRS_E_c04_DC YESNO 13 1 Spanningstype (gelijkstroom) 1 PARAM ab9d9956-a969-4f80-accf-cff7a80fcea3 NLRS_P_c13_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM ac0fbf49-c85a-413c-8a54-2fa4f7208661 NLRS_P_c16_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM ac2fe700-45cb-4793-80ad-04b5d4ba4b51 NLRS_P_c10_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM ac6d139c-10f5-45bc-b2b4-e5dea3257877 NLRS_P_c04_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM acb61923-d95d-486b-bf9d-506c23bd989f NLRS_P_c09_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM ada4895f-f390-4b05-9538-b930f77cca1d NLRS_P_c15_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM ade1b13c-211f-4a62-9e1c-3e8d2f1bad9d NLRS_P_c13_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM ae2e9a5e-5a88-4316-9c2d-94f5f5d79b4d NLRS_P_c13_diameter LENGTH 6 1 Diameter connector 1 PARAM afb2cc19-3061-415c-ac6a-52de29558f18 NLRS_P_c02_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM b0112718-3066-406a-a80a-ae1ba5e5434c NLRS_M_c04_breedte LENGTH 6 1 Breedte connector 1 PARAM b1b0911f-038a-440d-be7d-1027825db5c4 NLRS_M_c02_vrije_doorlaat NUMBER 8 1 Uitgedruk in %. Hoeveel % van de oppervlakte van een luchtrooster biedt geen obstakel voor de luchtstroom 1 PARAM b20004c9-90e0-4603-8fac-dedb8f865bce NLRS_E_c04_AC YESNO 13 1 Spanningstype (wisselstroom) 1 PARAM b211d8f2-1204-4b4b-88bf-23798d7fbbab NLRS_M_c03_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM b303dba0-aae0-4251-bdb5-4e5930308958 NLRS_P_c18_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM b3056140-bd37-43c9-8c6c-eacc9693dc25 NLRS_E_c03_aantal_polen NOOFPOLES 5 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM b32e724b-cb29-4a17-8b7b-badefd8c8a54 NLRS_P_c01_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM b39573c3-4f7c-42c1-a0c6-d47da4ceb2f0 NLRS_E_c04_actief_vermogen ELECTRICAL_POWER 36 1 Actief vermogen 1 PARAM b3b574b7-9978-4127-9edf-c7204daecc58 NLRS_E_c04_diameter LENGTH 6 1 Diameter connector (veelal bij Conduit Fittings) 1 PARAM b45bcf63-0255-4416-aa98-2f45ba0cf43f NLRS_P_c04_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM b48551c5-349f-476f-a6a2-7f5a82b7b634 NLRS_P_c07_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM b48a35d8-e897-496b-991a-f2d2f31204c6 NLRS_P_c02_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM b4ba8ce9-293a-44ab-b42e-00b5ec201998 NLRS_P_c03_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM b4d0ecec-aee0-4bb1-be94-febd9c50ae95 NLRS_P_c01_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM b59274ea-a943-457c-bd9e-a7e9f781addf NLRS_P_c18_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM b6221590-5810-4113-9134-7bcdfd18134f NLRS_M_c05_drukverlies_statisch HVAC_PRESSURE 37 1 Statisch drukverlies connector 1 PARAM b6a9eb0a-639f-4470-8f51-0f944d1b9f59 NLRS_P_c02_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM b6baf1ef-6104-46a1-85f2-75fc85df79b4 NLRS_E_c01_AC YESNO 13 1 Spanningstype (wisselstroom) 1 PARAM b70a1bdd-3902-4ec7-9614-7e48af755430 NLRS_P_c05_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM b820dc10-c0d3-438b-a6db-4ee8097c871d NLRS_P_c08_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM b8421734-78bb-47b8-82c9-55a9492767d3 NLRS_P_c16_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM b9769ac1-5e35-4d3e-8c81-fb98d46b0cb6 NLRS_M_c01_debiet HVAC_AIR_FLOW 22 1 Airflow van connector 1 PARAM b9e7c832-4d82-4560-baec-59f509cd54b4 NLRS_P_c16_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM ba55daec-e50c-4bbf-aae2-c0912f665632 NLRS_P_c15_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM bad80bbf-cbfb-44ba-aef4-9862aebef42d NLRS_P_c15_diameter LENGTH 6 1 Diameter connector 1 PARAM bbf08654-520b-45d2-88fb-0a933b6b7e46 NLRS_P_c04_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM bc237507-79f2-485f-8c18-3c294c2843ce NLRS_P_c13_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM bc9c2303-69ed-4deb-83a8-faa2424cb49d NLRS_E_c05_schijnbaar_vermogen_fase_3 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_3 op connector (Power - Unbalanced) 1 PARAM bcb5b6e5-56d7-490f-ab40-79c8300b5069 NLRS_P_c14_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM bd6dd5c4-7a7d-4b01-bb4a-c58465461698 NLRS_P_c13_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM be3dfcee-370c-490e-81c9-1513c1dc04cc NLRS_P_c11_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM bee8f483-f869-472d-9716-40819ed06250 NLRS_P_c06_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM bf6ade70-a325-46c0-ab06-f2cc910411e4 NLRS_P_c02_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM bf7c9bb4-518a-46dc-8435-12c937cb5cbf NLRS_E_c03_DC YESNO 13 1 Spanningstype (gelijkstroom) 1 PARAM bfc57a0f-bc8e-4f31-b1c9-8567ce81f547 NLRS_P_c04_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM c11ffdae-f2e0-4e87-9e6c-bc849c52c508 NLRS_E_c01_stroom ELECTRICAL_CURRENT 15 1 Nominale stroom van connector 1 PARAM c16f7515-3be1-443e-a36c-ef89dc408b30 NLRS_E_c03_aantal_fasegeleiders INTEGER 19 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM c226b0ca-f2f2-4eae-98d9-75bc0f36b2ce NLRS_M_c04_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM c329bd29-907b-4ab0-bd90-f91b4327673e NLRS_P_c05_radius LENGTH 6 1 Radius connector 1 PARAM c347cda7-72ff-4a28-9b50-1b68cc825abb NLRS_P_c05_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM c35ac6ad-69a0-466c-b78c-19d7f2bcb719 NLRS_M_c04_debiet HVAC_AIR_FLOW 22 1 Airflow van connector 1 PARAM c4726202-1043-42d1-80ed-0d544110eeaf NLRS_E_c02_schijnbaar_vermogen_fase_2 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_2 op connector (Power - Unbalanced) 1 PARAM c557eb71-9487-461e-8cc3-24a3959096c0 NLRS_P_c17_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM c5b6b2d8-5e9b-495f-9d29-f7ee571b65ec NLRS_P_c03_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM c5f92774-1e2e-4b1a-9b19-c4f9ea4a9269 NLRS_M_c02_debiet HVAC_AIR_FLOW 22 1 Airflow van connector 1 PARAM c64082c6-5aa0-4886-bc41-88c039f749b2 NLRS_E_c02_breedte LENGTH 6 1 Breedte connector (veelal bij Cable Tray Fittings) 1 PARAM c6a1da2a-1945-4940-a5b0-28c7476f3bce NLRS_P_c01_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM c73d78aa-28fe-4552-b8e5-a5d6cfdeeadf NLRS_E_c04_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter. 'Angle' bij Conduit- en Cable Tray connectoren) 1 PARAM c79529de-b320-4260-90e8-cecf36f7a350 NLRS_P_c16_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM c9095d76-b0cf-453b-a126-64f3b7f12065 NLRS_P_c13_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM c9618685-7de5-4426-aa71-46d74b992475 NLRS_P_c11_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM c9691820-29e3-4f72-8cfc-4826e2de8d04 NLRS_P_c03_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM c98c5cf8-5db6-4c6f-8865-459d079efa5b NLRS_P_c17_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM ca0d6270-0d17-4acb-99cd-108fd10c77ed NLRS_P_c05_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM cabc6054-824a-4e68-b39c-4a91876f4bf0 NLRS_P_c10_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM cac3fa68-2221-4214-9263-66b91a2c06c7 NLRS_E_c04_schijnbaar_vermogen ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - balanced) 1 PARAM cb1b5288-f275-4a27-9eee-3958ce8a49c6 NLRS_P_c04_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM cb38e2be-d5f7-4f30-9dcf-26dc5a9efb4d NLRS_P_c12_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM cba83bc4-85e5-4583-a648-ed3f1852b60e NLRS_M_c05_debiet HVAC_AIR_FLOW 22 1 Airflow van connector 1 PARAM cbaf05a9-8b44-4580-8f9f-5d91d2d64d25 NLRS_P_c18_radius LENGTH 6 1 Radius connector 1 PARAM cbd3c2f1-8197-4f27-8b89-13227636ffbc NLRS_P_c18_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM cbec7be1-9537-4c5e-8b36-577fbc947b66 NLRS_E_c03_verbruiker_ster_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM cc0dd189-6e86-4ac4-9842-ef6f24abae60 NLRS_P_c13_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM ce53179c-841e-4f7c-882f-b2295d1e2cb6 NLRS_M_c04_diameter LENGTH 6 1 Diameter connector 1 PARAM cfa9247a-d5fa-4e6c-a6da-715f3d8a69a9 NLRS_E_c02_schijnbaar_vermogen ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_1 op connector (Power - balanced) 1 PARAM d0515b1d-6d79-41f3-9892-9456f826c84b NLRS_P_c11_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM d0807316-f504-42df-8bf3-7e2d55f8cb16 NLRS_P_c08_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM d1122545-afd3-4e8b-bc9e-b36f472bcb73 NLRS_E_c04_aantal_polen NOOFPOLES 5 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM d11fbc83-7b6b-4457-b9a1-ce591d778671 NLRS_M_c04_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM d14da677-804f-4fd1-8abb-a1f8d1e964c5 NLRS_P_c04_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM d1504b91-b750-4a9c-a4d6-83630f7dba88 NLRS_E_c03_hoogte LENGTH 6 1 Hoogte connector (veelal bij Cable Tray Fittings) 1 PARAM d1986189-24b6-4a27-b6fc-6fb9214baf74 NLRS_E_c05_schijnbaar_vermogen_fase_2 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_2 op connector (Power - Unbalanced) 1 PARAM d1b2ef37-3584-44f5-9151-3332898135fb NLRS_P_c14_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM d1d6866e-b7e3-4924-adb4-e1b30fc38ac6 NLRS_M_c05_temperatuur HVAC_TEMPERATURE 27 1 Temperatuur medium dat door connector stroomt 1 PARAM d2f0d35a-e390-4baf-a4ad-fc18cf88a5ca NLRS_P_c14_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM d46193f9-fc7e-45a0-8b0c-aafc73bbea2b NLRS_E_c05_aantal_polen NOOFPOLES 5 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM d63f2382-8486-4de0-8620-fed1fa38f42f NLRS_E_c04_subklasse_motor YESNO 13 1 Wanneer de electrical connector de connector is van een motor dan moet dit aangevinkt staan. Ongetwijfeld wordt hier gebruik van gemaakt bij load classification. 1 PARAM d6a96d2b-66fa-45a9-81cd-d6d5a6c5c64c NLRS_M_c03_straal LENGTH 6 1 Radius connector 1 PARAM d7ab97de-5e50-4432-b507-7c32a9b30f5f NLRS_P_c17_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM d7e1185d-7242-4143-83fc-453e31c52c25 NLRS_E_c05_spanning ELECTRICAL_POTENTIAL 17 1 Spanning van de connector. (is een te koppelen parameter. 'Voltage' bij Electrical connectoren) 1 PARAM d811f032-171e-4e81-8e3e-a36ad9f3c2e5 NLRS_M_c02_temperatuur HVAC_TEMPERATURE 27 1 Temperatuur medium dat door connector stroomt 1 PARAM d8cc99a2-5090-46e2-9222-b46b501c4f84 NLRS_P_c17_radius LENGTH 6 1 Radius connector 1 PARAM d9074641-3638-44d8-be07-e65c29d598e4 NLRS_E_c05_actief_vermogen ELECTRICAL_POWER 36 1 Actief vermogen 1 PARAM d97d2a44-5c40-444a-9bd1-c12a6e00582a NLRS_P_c07_diameter LENGTH 6 1 Diameter connector 1 PARAM d9cac7ed-3028-4062-a39d-7041948d7b33 NLRS_P_c01_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM da164489-7396-4693-9cd3-144be9da13e6 NLRS_P_c14_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM da968e16-315e-4ad9-b50e-b2490b2fda35 NLRS_M_c02_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM db876781-a976-4e26-a196-0a3d5511f570 NLRS_E_c04_verbruiker_driehoek_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM dc499895-278b-4fd4-8c88-00c7f4b2b569 NLRS_P_c12_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM dc7b9158-62a6-404a-8bb9-839dcc306112 NLRS_E_c04_hoogte LENGTH 6 1 Hoogte connector (veelal bij Cable Tray Fittings) 1 PARAM dd462c8c-a967-40bf-b1bb-e63213906db0 NLRS_P_c13_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM dea745aa-dc9b-4b5f-8677-f0686d9a3b47 NLRS_P_c09_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM dea8b0f0-a59e-4946-a21e-aeb3eeeaf1bb NLRS_P_c14_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM df26aac7-c2c8-493e-b04e-01b50ac43c21 NLRS_P_c17_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM df405bae-64b6-4262-819f-40fe6bdc3bf2 NLRS_P_c04_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM df4cffad-280f-4c27-a815-8a99aa53712f NLRS_P_c15_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM df6423ed-fbe7-4464-9639-cb0648c1418e NLRS_E_c03_stroom ELECTRICAL_CURRENT 15 1 Nominale stroom van connector 1 PARAM dfa2f5db-0fa3-4a13-aba0-2d3eb1963e4e NLRS_P_c10_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM e018314c-e3db-4248-addc-9e458e9018c7 NLRS_E_c05_verbruiker_ster_geschakeld YESNO 13 1 Of een driefasige gebruiker in ster of in driehoek geschakeld is bepaalt de stroom die uiteindelijk zal stromen in de geleiders. Sommige motoren starten in ster om dan over te gaan in driehoek. Met deze parameter kan dit - indien gewenst - gesimuleerd worden. 1 PARAM e04b0c69-9b53-450f-b6d8-7715072c5695 NLRS_P_c14_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM e18c5b79-d542-4e03-803d-02f2f143113b NLRS_M_c02_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM e22bfbf8-8455-46c8-b54d-871470e4639f NLRS_P_c17_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM e49c4e7a-8167-49df-97b3-e0ad385e4c0c NLRS_P_c07_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM e4ab6e1e-1101-4c6b-8909-fa3e022c750a NLRS_E_c02_radius LENGTH 6 1 Radius connector (veelal bij Conduit Fittings) 1 PARAM e4acd6fa-e8a2-45c7-bccf-3e8cc7e3f0d3 NLRS_P_c09_belastingswaarde_eenheid TEXT 10 1 Deze parameter is aanvullend op de parameter 'belastingswaarde' en geeft aan in welke eenheden de belastingswaarde is uitgedrukt. 1 PARAM e4ca3178-70e2-4563-9e08-1214d2cf1449 NLRS_P_c17_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM e4cb55d1-72f6-415b-9c60-39203f2d6413 NLRS_E_c05_aantal_fasegeleiders INTEGER 19 1 aantal fasegeleiders is kleiner dan of gelijk aan het aantal polen. Bij 1N230V is het aantal fasegeleiders 1 en het aantal polen 2; bij 3,230V is zowel het aantal fasegeleiders als het aantal polen gelijk aan 2 voor een monofasig stopcontact dat hierop aangesloten wordt; revit gebruikt de verkeerde terminologie zodat dit verwarrend overkomt. Aantal fasegeleiders is de te koppelen parameter! 1 PARAM e6739f45-6b5a-4ecd-b623-8e0f5464d475 NLRS_P_c08_druktrap TEXT 10 1 Druktrap van de connector. Mappen met ETIM feature 'Druktrap flens' EF020149 1 PARAM e6b1dd23-b1d2-435d-ae0c-78cbd57233ab NLRS_M_c03_debiet HVAC_AIR_FLOW 22 1 Airflow van connector 1 PARAM e6c0283e-b72e-4d8f-a0f1-581f93ed9140 NLRS_P_c06_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM e76b8391-d578-4575-a2d9-60ab3cb46856 NLRS_P_c08_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM e8841c20-1cde-42f9-a5ba-505e419e1a84 NLRS_P_c05_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM e89d0f31-5d6f-43c9-b763-491d063fdcca NLRS_E_c05_stroom ELECTRICAL_CURRENT 15 1 Nominale stroom van connector 1 PARAM e8eae8ee-2c1e-4d77-b331-eff25eab4c92 NLRS_P_c16_aansluitmethode LENGTH 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM e95f3a3f-dd9c-4be6-8f00-c7c8e124e35a NLRS_P_c04_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM ea424b24-a61e-4069-9ea2-0f6aeac8c588 NLRS_P_c17_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM ea9c940a-57ca-4e3f-8af3-5602ef22ac17 NLRS_P_c06_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM eae5b3a1-0707-478c-90ef-57b8fc5957f6 NLRS_P_c02_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM eaff5524-3dc9-424c-bd5a-faf4f9675db6 NLRS_P_c11_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM ec4ca462-ef84-4ad5-ba1e-809c8a8520cd NLRS_P_c16_radius LENGTH 6 1 Radius connector 1 PARAM eca5b7ca-9582-42d0-8198-c3a2f7ee6fb8 NLRS_P_c08_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM eca8be31-8ea8-43d3-9517-cff2e3060879 NLRS_E_c01_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter. 'Angle' bij Conduit- en Cable Tray connectoren) 1 PARAM ecbf95c4-1477-4de5-9ab1-c5aca383e760 NLRS_M_c03_temperatuur HVAC_TEMPERATURE 27 1 Temperatuur medium dat door connector stroomt 1 PARAM ed48aecf-39f4-4471-842e-b27a92cf2a86 NLRS_P_c18_diameter LENGTH 6 1 Diameter connector 1 PARAM edadc90e-fa68-4f5b-9e4d-ceac914ca756 NLRS_P_c01_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM ee6a6d66-57be-48bc-b9fb-7d2181e9c896 NLRS_P_c12_hellingsaanpassingen YESNO 13 1 Geeft aan dat er onder een helling op de connectot kan worden aangesloten 1 PARAM ee7a0f21-0835-44ba-b78f-828055676604 NLRS_P_c03_radius LENGTH 6 1 Radius connector 1 PARAM eeb90379-b0c4-4f88-8b1b-ebc6e936a6b7 NLRS_E_c01_schijnbaar_vermogen_fase_2 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_2 op connector (Power - Unbalanced) 1 PARAM f03bb833-4ce6-42eb-9738-41fb16eae6c7 NLRS_P_c13_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM f07302d9-667a-48f1-bd41-a7e6834966dc NLRS_P_c03_normdebiet PIPING_FLOW 29 1 Normdebiet bij atmosferische omstandigheden in persluchtsystemen. 1 PARAM f08f2f99-f823-4f63-91b9-fcdd01f5b0df NLRS_P_c17_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM f0e42a53-ee51-4a47-b262-2020a3ec7104 NLRS_P_c01_inhoud VOLUME 12 1 De totale inhoud van het leidingenstelsel in de component dat is aangesloten op deze connector, uitgedrukt in m³. Bij een naverwarmingsbatterij zal op beide connector de volledige waterinhoud vermeld worden! 1 PARAM f172d2cd-70d7-4673-8b5d-ed40894c0e64 NLRS_P_c11_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM f17f285e-2099-41bd-9742-013e7fdf312d NLRS_P_c10_diameter LENGTH 6 1 Diameter connector 1 PARAM f2ce87b5-9d0c-4d0e-8672-335bc1d28eb5 NLRS_P_c12_opvoerhoogte PIPING_PRESSURE 31 1 Opvoerhoogte connector 1 PARAM f3767c94-9bcf-409f-b2a1-16111ef698d9 NLRS_P_c09_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM f3997781-f344-454a-a6e2-cb7ed98a6007 NLRS_P_c07_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM f3ae5fc0-42a3-48da-9bfc-1400b8f529c5 NLRS_P_c18_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM f3f77889-00bb-4019-99cd-898593f42bc1 NLRS_P_c10_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM f3f8efcd-fafd-4ec0-bdf1-e9c45818dfc8 NLRS_P_c03_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM f43382c0-28df-424f-9f44-9fb4d750ef2b NLRS_P_c12_radius LENGTH 6 1 Radius connector 1 PARAM f451003f-fad1-4524-b97a-2cc53c2d2259 NLRS_P_c13_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM f5158128-0057-4f99-8197-dfc1098a1341 NLRS_P_c15_aansluitmethode TEXT 10 1 Aansluitmethode connector. Mappen met ETIM feature 'Aansluiting' EF000443 1 PARAM f51cc660-2b05-43c0-bbd6-9eafab8e42fd NLRS_P_c01_drukverlies_statisch PIPING_PRESSURE 31 1 Statisch drukverlies connector 1 PARAM f54a2fe1-c24f-46f9-8c6f-ca5d9e2caab7 NLRS_P_c06_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM f57b2709-a27e-475e-9653-d53fb6ecce09 NLRS_P_c12_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM f5d895f0-4d59-4a4a-9ab9-5763a632d2c1 NLRS_P_c13_volumestroom PIPING_FLOW 29 1 Volumestroom connector 1 PARAM f68fe38e-6621-4fdc-ae64-4f865224e36d NLRS_M_c05_vrije_doorlaat NUMBER 8 1 Uitgedruk in %. Hoeveel % van de oppervlakte van een luchtrooster biedt geen obstakel voor de luchtstroom 1 PARAM f6b47d0d-1ba3-4191-9e75-161772b35623 NLRS_E_c01_schijnbaar_vermogen_fase_3 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_3 op connector (Power - Unbalanced) 1 PARAM f8b15ca9-6910-4fe3-91f2-2ed3e954bb94 NLRS_P_c07_druk_statisch PIPING_PRESSURE 31 1 De statische druk die heerst ter hoogte van de connector uitgedrukt in Pa. Hydrostatische druk in het geval van water. BEREKENDE WAARDE. 1 PARAM f91172b3-77a0-473a-ad84-544d9afc0062 NLRS_E_c02_schijnbaar_vermogen_fase_3 ELECTRICAL_APPARENT_POWER 14 1 schijnbaar_vermogen_fase_3 op connector (Power - Unbalanced) 1 PARAM f93207c1-1fdd-4b2f-872f-f12cea86f51f NLRS_M_c05_hoek ANGLE 1 1 Hoek connector(is een te koppelen parameter in een Pipe connector. Angle bij Pipe Fittings) 1 PARAM f93d68a5-28bb-49d1-80b3-497ccf69c994 NLRS_P_c07_belastingswaarde_eenheid_omschrijving TEXT 10 1 Formule die de parameter belastingswaarde_eenheid omzet in een leesbare tekst. Mogelijke waarden zijn voor de NLRS 0 'C - constant'; 1 'TE - tapeenheden'; 2 'SE - spoeleenheden'. Een waarde kleiner dan 0 wordt omgezet naar 'C - constant' een waarde groter dan 2 naar 'SE - spoeleenheden' 1 PARAM fa247e45-5272-45c9-a2a0-8c503ec5bc11 NLRS_P_c18_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM fa5fa396-5dc8-4b61-b58c-1cd850d53a04 NLRS_P_c08_temperatuur PIPING_TEMPERATURE 32 1 Temperatuur medium dat door connector stroomt 1 PARAM fa678965-5f66-4ee2-a28b-7edce66d08c2 NLRS_P_c01_radius LENGTH 6 1 Radius connector 1 PARAM fbac6039-444b-4439-a298-16b5d98cb108 NLRS_E_c02_diameter LENGTH 6 1 Diameter connector (veelal bij Conduit Fittings) 1 PARAM fc647aa5-ee0f-48f4-8005-35494477887b NLRS_E_c03_breedte LENGTH 6 1 Breedte connector (veelal bij Cable Tray Fittings) 1 PARAM fc68e8b9-54aa-438a-8794-45a241c79304 NLRS_M_c01_omschrijving TEXT 10 1 Omschrijving connector 1 PARAM fd070246-6bd9-41a2-87d2-bafdcf0c43d6 NLRS_P_c12_belastingswaarde FIXTUREUNIT 28 1 Aantal tapeenheden of spoeleenheden. bv 1 of 0,5 1 PARAM fe0dacef-3a16-4073-815b-cf9865e72cde NLRS_E_c04_breedte LENGTH 6 1 Breedte connector (veelal bij Cable Tray Fittings) 1 PARAM cb87e84d-211e-43fe-8241-22a7f2ef8064 NLRS_P_c01_lengte_01 LENGTH 6 1 1 PARAM f42d0eee-0a44-4bae-b3f2-a8490024cff6 NLRS_P_c01_lengte_02 LENGTH 6 1 1 PARAM d332a9cf-801c-4014-aa75-f84d90e9ebb4 NLRS_P_c01_diameter_02 LENGTH 6 1 1 PARAM 7f19ccc2-d0a9-40c9-bf8a-51a4b8895ee5 NLRS_P_c02_lengte_01 LENGTH 6 1 1 PARAM 8a3473b7-35db-449a-8289-e02defea6bf5 NLRS_P_c02_lengte_02 LENGTH 6 1 1 PARAM ad5f9ad1-3770-49e8-82d5-0597ad341c81 NLRS_P_c02_diameter_02 LENGTH 6 1 1